SOP on Cleaning of Rotary Tablet counter
Objective : To describe cleaning procedure for rotary tablet counter.
Scope : To ensure that the equipment is clean and free from any starting materials of previous batch or product residues.
Responsibility : 1.It is the responsibility of operating staff to clean the equipment.
2. Production Chemist to ensure that procedure is followed.
Materials & Equipment :
1. Cleaning agent: Isoprpyl alcohol (70%v/v)
2. Mops / lint free cloth
Procedure
(1) Remove any visible materials from the tablet counter with the help of a jet of compressed air.
(2) Dismantle the counter plate from its holder plate.
(3) Clean the counter plate and its holder plate with a dry lint free cloth.
(4) Again clean both with the help of wet mop soaked in purified water and squeezed.
(5) Mop the plates with 70% v/v Isopropyl alcohol and allow them to dry in air.
(6) Reassemble the counter plate on the holder plate.
(7) After getting authorization from QC Chemist, put a label “Cleaned” or “Ready for use”.